- (a)Breathing bags will be tested in an air atmosphere saturated with gasoline vapor at room temperature (24-30 °C./75-85 °F.) for a continuous period of twice the rated time of the apparatus (except for apparatus for escape only where the test period shall be the rated time of the apparatus).
- (b)The bag will be operated during this test by a breathing machine with 24 respirations per minute and a minute-volume of 40 liters.
- (c)A breathing machine cam with a work rate of 622 kp.-m./min. will be used. The dimensions of a suitable breathing machine cam are available from the Institute upon request.
- (d)The air within the bag(s) shall not contain more than 100 parts per million of gasoline vapor at the end of the test.