43 CFR §3175.141
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Test facility. All testing must be performed by a qualified test facility not affiliated with the flow-computer manufacturer.
- (b)Selection of flow-computer software to be tested.
- (c)Testing method. Input variables may be either:
- (d)Pass-fail criteria.
- (1)For each test listed in §§ 3175.142 and 3175.143, the value(s) required to be calculated by the software version under test must be compared to the value(s) calculated by BLM-approved reference software, using the same digital input for both.
- (2)The software under test may be used at an FMP only if the difference between all values calculated by the software version under test and the reference software is less than 50 parts per million (0.005 percent) and the results of the tests required in §§ 3175.142 and 3175.143 are satisfactory to the PMT. If the test results are satisfactory, the BLM will identify the software version tested as acceptable for use on its website at www.blm.gov.