  1. (a)Instantaneous flow rate. The instantaneous flow rates must meet the criteria in § 3175.141(d) for each test identified in Table 1 to this section, using the gas compositions identified in Table 2 to this section, as prescribed in Table 1 to this section.
  2. (b)Sums and averages.
    1. (1)Fixed input values from test 2 in Table 1 to this section must be applied for a period of at least 24 hours.
    2. (2)At the conclusion of the 24-hour period, the following hourly and daily values must meet the criteria in § 3175.141(d):
      1. (i)Volume;
      2. (ii)Integral value;
      3. (iii)Flow time;
      4. (iv)Average differential pressure;
      5. (v)Average static pressure; and
      6. (vi)Average flowing temperature.
  3. (c)Other tests. The following additional tests must be performed on the flow-computer software:
    1. (1)Each parameter of the configuration log must be changed to ensure the event log properly records the changes according to the variables listed in § 3175.104(c); and
    2. (2)Inputs simulating a 15 percent and 150 percent over-range of the differential and static-pressure transducer's calibrated span must be entered to verify that the over-range condition triggers an alarm or an entry in the event log.