- (a)Each direct current ship's service switchboard must have the equipment required by paragraphs (b) through (f) of this section.
- (b)For each connected generator, each switchboard must have the following:
- (1)A circuit breaker that meets § 111.12-11 and § 111.50-5.
- (2)A disconnect switch or link for each generator conductor, except a switchboard having a draw-out or plug-in type generator circuit breaker that disconnects—
- (3)A field rheostat.
- (4)An indicator light connected between the generator and circuit breaker.
- (c)For each two-wire generator, each switchboard must have:
- (d)For each three-wire generator, each switchboard must have the following:
- (e)Each switchboard must have ground detection that meets subpart 111.05 for the:
- (f)For each shore power connection, each switchboard must have:
- (g)One of the voltmeters under paragraph (c)(2) or (d)(3) of this section must be connected to show: