46 CFR §111.81-1
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)The requirements of this subpart apply to each outlet box used with a lighting fixture, wiring device, or similar item, including each separately installed connection and junction box.
- (b)An outlet box must be at each outlet, switch, receptacle, or junction point.
- (c)Each outlet or junction box must have a cover unless a fixture canopy, switch cover, receptacle cover, or other cover is used.
- (d)As appropriate, each outlet-box or junction-box installation must meet the following standards (all incorporated by reference, see § 110.10-1 of this subchapter): Article 314 of NFPA 70; ANSI/UL 50; ANSI/UL 514A, ANSI/UL 514B, and ANSI/UL 514C; IEC 60092-101:2018; IEC 60092-201:2019; IEC 60092-306:2009; IEC 60092-352:2005; IEC 60092-401:1980; and IEC 60092-502:1999.
- (e)Each outlet or junction box must be securely attached to its mounting and be affixed so as to maintain its designated degree of protection.
- (f)Each outlet and junction box must be suitable for the environment in which it is installed and be constructed to the appropriate NEMA or IEC standard.