46 CFR §112.15-5
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
On vessels required to have a final emergency power source by § 112.05-5(a) of this chapter, the following emergency lighting and power loads must be arranged so that they can be energized from the final emergency power source:
- (a)Each load under § 112.15-1.
- (b)The machinery, controls, and alarms for each passenger elevator.
- (c)Each charging panel for:
- (d)One of the bilge pumps, if the emergency power source is its source of power to meet Part 56 of this chapter.
- (e)One of the fire pumps, if the emergency power source is its source of power to meet the requirements of the subchapter under which the vessel is certificated.
- (f)Each sprinkler system, water spray extinguishing system, or foam system pump.
- (g)If necessary, the lube oil pump for each propulsion turbine and reduction gear, propulsion diesel reduction gear, and ship's service generator turbine which needs external lubrication.
- (h)Each rudder angle indicator.
- (i)Each radio or global maritime distress and safety system (GMDSS) component.
- (j)Each radio direction finder, radar, gyrocompass, depth sounder, global positioning system (GPS), satellite navigation system (SATNAV), speed log, rate-of-turn indicator and propeller pitch indicator.
- (k)Each steering gear feeder, if required by part 58, subpart 58.25, of this chapter.
- (l)Each general emergency alarm flashing light required by § 113.25-10 of this chapter.
- (m)Each electric blow-out-preventer control system.
- (n)Any permanently installed diving equipment that is dependent upon the vessel's or drilling unit's power.
- (o)Each emergency generator starting compressor, as allowed by § 112.50-7(c)(3)(ii).
- (p)Each steering gear failure alarm required by part 113, subpart 113.43, of this chapter.
- (q)The ballast control system on each column-stabilized mobile offshore drilling unit.
- (r)Each vital system automation load required by part 62 of this chapter.
- (s)Motor-operated valves for each cargo oil and fuel oil system, if the emergency power source is the source of power to meet § 56.60(d) of this chapter.
- (t)Each ship's stabilizer wing, unless a separate source of emergency power is supplied.
- (u)Each indicator that shows the position of the stabilizer wings, if the emergency power source is its emergency source of power.
- (v)Each smoke extraction fan, not including smoke detector sampling, and carbon dioxide or clean agent exhaust fans for spaces.