46 CFR §129.340
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)If individual wires, rather than cables, are used in systems operating at a potential of greater than 50 volts, the wire and associated conduit must be run in a protected enclosure. The protected enclosure must have drain holes to prevent the buildup of condensation.
- (b)Each cable and wire must—
- (1)Have stranded copper conductors with sufficient current-carrying capacity for the circuit in which it is used;
- (2)Be installed so as to avoid or reduce interference with radio reception and compass indication;
- (3)Be protected from the weather;
- (4)Be supported so as to avoid chafing or other damage;
- (5)Be installed without sharp bends;
- (6)Be protected by metal coverings or other suitable means, if in areas subject to mechanical abuse;
- (7)Be suitable for low temperature and high humidity, if installed in refrigerated compartments;
- (8)Be located outside a tank, unless it supplies power to equipment in the tank; and
- (9)Have sheathing or wire insulation compatible with the fluid in a tank, when installed to comply with paragraph (b)(8) of this section.
- (c)Cable and wire in power and lighting circuits must be #14 AWG or larger. Cable and wire in control and indicator circuits must be #22 AWG or larger, or be ribbon cable or similar, smaller, conductor-size cable recommended by the equipment manufacturer for use in circuits for low-power instrumentation, monitoring, or control.
- (d)Cable and wire for power and lighting circuits must—
- (1)Comply with Section 310-13 of the NEC (NFPA 70), except that no asbestos-insulated cable or dry-location cable may be used;
- (2)Be listed by Underwriters Laboratories, Inc. as UL Boat or UL Marine Shipboard cable; or
- (3)Comply with § 111.60-1 of this chapter for cable, and § 111.60-11 of this chapter for wire.
- (e)Cable and wire serving vital systems listed in § 128.130(a) of this subchapter or serving emergency loads must be routed as far as practicable from areas at high risk for fire, such as galleys, laundries, and machinery spaces.
- (f)Cable or wire serving duplicated equipment must be separated so that a casualty that affects one cable does not affect the other.
- (g)Each connection to a conductor or a terminal part of a conductor must be made within an enclosure and—
- (h)A connector or lug of the set-screw type must not be used with a stranded conductor smaller than No. 14 AWG, unless there is a nonrotating follower that travels with the set screw and makes pressure contact with the conductor.
- (i)Each pressure-type wire connector and lug must comply with UL 486A. No wire nuts may be used.
- (j)Each terminal block must have terminal screws 6-32 or larger.
- (k)Each wire connector used in conjunction with screw-type terminal blocks must be of the captive type such as the ring or the flanged-spade type.
- (l)No cable may be spliced in—
- (1)A hazardous location; or
- (2)Another location, except—
- (i)A cable installed in a subassembly may be spliced to a cable installed in another subassembly;
- (ii)For a vessel receiving alterations, a cable may be spliced to extend a circuit;
- (iii)A cable of large diameter or exceptional length may be spliced to facilitate its installation.
- (iv)A cable may be spliced to replace a damaged section of itself if, before replacement of the damaged section, the insulation resistance of the remainder of the cable is measured, and the condition of the insulation is unimpaired.
- (m)All material in a cable splice must be chemically compatible with other material in the splice and with the materials in the cable.
- (n)Ampacities for conductors must comply with Section 310-15 of the NEC (NFPA 70), or with IEEE Standard 45, as appropriate.
- (o)Each conductor must be sized so that the voltage drop at the load terminals does not exceed 10 percent.
- (p)Each metallic covering of armored cable must—
- (q)Each portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 of this chapter for flexible electric cord or cable.