46 CFR §130.450
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Each alarm required by § 130.460 of this subpart must be of the self-monitoring type that will both show visibly and sound audibly upon an opening or break in the sensing circuit.
- (b)The visible alarm must show until it is manually acknowledged and the condition is corrected.
- (c)The audible alarm must sound until it is manually silenced.
- (d)No silenced alarm may prevent any other audible alarm from sounding.
- (e)Each OSV must be provided with means for testing each visible and audible alarm.
- (f)Each OSV must provide battery power for the alarm required by § 130.460(a)(8) of this subpart.