46 CFR §133.170
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)General. Each OSV must have a line-throwing appliance that is approved under approval series 160.031 or 160.040.
- (b)Stowage. The line-throwing appliance and its equipment must be readily accessible for use.
- (c)Additional equipment. Each OSV must carry the following equipment for the line-throwing appliance:
- (1)The equipment on the list provided by the manufacturer with the approved appliance.
- (2)An auxiliary line that—
- (i)For an appliance approved under approval series 160.040, is at least 450 meters (1,500 feet) long;
- (ii)For an appliance approved under approval series 160.031, is at least 150 meters (500 feet) long;
- (iii)Has a breaking strength of at least 40 kiloNewtons (9,000 pounds-force); and
- (iv)Is, if synthetic, a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light.