- (a)Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use.
- (b)If a storage room is provided, it may be any room or compartment that is free of ignition sources.
- (c)If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either:
- (1)A flammable liquid storage cabinet that satisfies UL 1275 (incorporated by reference, see § 136.112 of this subchapter); or
- (2)A flammable liquid storage cabinet that satisfies FM Approvals Standard 6050 (incorporated by reference, see § 136.112 of this subchapter); or
- (3)Another suitable steel container that provides an equivalent level of protection.