- (a)Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent.
- (b)Pressure vessels must be externally examined annually. Relief valves must be tested in accordance with § 143.245.
- (c)All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew.
- (d)Pressure vessels installed after July 20, 2018, or the date the vessel obtains a Certificate of Inspection (COI), whichever date is earlier, must meet the requirements of § 143.545.