46 CFR §153.481
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
Unless waived under § 153.483 or § 153.491, each Category B NLS cargo tank on ships built before July 1, 1986 must meet the following:
- (a)Unless the tank meets the interim standard provided by paragraph (b) of this section and is prewashed in accordance with § 153.1118, the tank must have a stripping quantity determined under § 153.1604 that is less than 0.35m 3.
- (b)Before October 3, 1994, the tank may have a total NLS residue determined under § 153.1608 that is less than 1.0 m 3 or 1/3000th of the tank's capacity and an NLS residue discharge system meeting the following:
- (1)The system must be capable of discharging at a rate equal to or less than Q in the following formula:
- (2)The system must have equipment capable of automatically recording—
- (3)Each system that has the capacity to exceed Q calculated in paragraph (b)(1) of this section must have equipment that—
- (4)Each system that has the capacity to exceed Q calculated under paragraph (b)(1) of this section and does not automatically control the flow rate must have—
- (i)Manual controls that enable the flow to be adjusted to the value of Q calculated in paragraph (b)(1) of this section and that must be moved through at least 25% of their total range of movement for the discharge rate to change from 0.5Q to 1.5Q; and
- (ii)A flow rate meter located where the flow is manually controlled.