46 CFR §154.1165
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Each dry chemical hand hose line must be one that can be actuated at its hose reel or hose storage cabinet.
- (b)Each dry chemical monitor must be one that can be actuated and controlled at the monitor.
- (c)A dry chemical monitor for the cargo loading and discharging manifold areas must be one that can be:
- (d)Each dry chemical storage unit must have independent piping with a stop valve in the piping for each remote hand hose line and remote monitor where the piping connects to the storage container, if the unit has:
- (e)Each stop valve under paragraph (d) of the section must be capable of:
- (f)Damage to any dry chemical system hose, monitor, pipe or control circuits must not prevent the operation of other hoses, monitors, or control circuit that are connected to the same storage unit.