- (a)Vessels of less than 65 feet in length must have a portable hand bilge pump having a maximum capacity of 5 gpm.
- (b)In addition to the requirements of paragraph (a) of this section, vessels of 26 feet but less than 40 feet in length must have a fixed hand bilge pump or fixed power bilge pump having a minimum capacity of 10 gpm. If a fixed hand pump is installed, it must be operable from on deck.
- (c)In addition to the requirements of paragraph (a) of this section, vessels of 40 feet but less than 65 feet must have a fixed power bilge pump having a minimum capacity of 25 gpm.
- (d)Vessels of 65 feet in length but less than 120 feet and under 100 gross tons must have two fixed power bilge pumps having a combined minimum capacity of 50 gpm.
- (e)Vessels of 120 feet or greater and vessels of 100 gross tons and over must have two fixed power pumps meeting the capacity requirements of § 56.50-55(c) of this chapter.
- (f)Each power driven bilge must be self priming.
- (g)Each fixed bilge pump required by this section must be permanently connected to the bilge main.
- (h)Bilge pumps may also be connected to the firemain provided that the bilge system and firemain system may be operated simultaneously.