In lieu of the remote stopping systems required by subpart 111.103 of this chapter, remote stop stations must be provided as follows:
- (a)A propulsion shutdown in the pilothouse for each propulsion unit,
- (b)A bilge slop or dirty oil discharge shutdown at the deck discharge,
- (c)A ventilation shutdown located outside the space ventilated, and
- (d)A shutdown from outside the engineroom for the fuel transfer pump, fuel oil service pump, or any other fuel oil pump.