StacksVerified U.S. regulatory reference

46 CFR §172.240

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov
When doing the calculations required in § 172.225,
  1. (a)The permeability of a floodable space, other than a machinery or cargo space, must be assumed as listed in Table 172.240;
  2. (b)Calculations in which a machinery space is treated as a floodable space must be based on an assumed machinery space permeability of 85% unless the use of an assumed permeability of less than 85% is justified in detail; and
  3. (c)Calculations in which a cargo space that is completely filled is considered flooded must be based on an assumed cargo space permeability of 60% unless the use of an assumed permeability of less than 60% is justified in detail. If the cargo space is not completely filled, a cargo space permeability of 95% must be assumed unless the use of an assumed permeability of less than 95% is justified in detail.