46 CFR §179.330
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Hinged watertight doors are not permitted in bulkheads required by § 179.210 or § 179.212 unless the vessel will not proceed more than 20 nautical miles from shore and:
- (1)The door separates a machinery space from an accommodation space and, in the judgment of the cognizant OCMI, the door will be kept closed except when a person is passing through the door; or
- (2)The Commandant determines that, due to the arrangements of the vessel, the door will be kept closed except when a person is passing through the door.
- (b)A hinged watertight bulkhead door must be fitted with a quick action closing devise operable from both sides of the door and indicator lights at the operating station showing whether the door is open or closed.
- (c)Sliding watertight doors must meet the requirements of part 170, subpart H in subchapter S of this chapter.
- (d)No more than one watertight door may be fitted in a watertight bulkhead, and it must be located as high and as far inboard as practicable.