46 CFR §56.90-5
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)All flanged joints must be fitted up so that the gasket contact faces bear uniformly on the gasket and then must be made up with relatively uniform bolt stress.
- (b)When bolting gasketed flanged joints, the gasket must be properly compressed in accordance with the design principles applicable to the type of gasket used.
- (c)Steel to cast iron flanged joints shall be assembled with care to prevent damage to the cast iron flange in accordance with § 56.25-10.
- (d)All bolts must be engaged so that there is visible evidence of complete threading through the nut or threaded attachment.