49 CFR §178.255-1
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Tanks must be of fusion welded construction, cylindrical in shape with seamless heads concave to the pressure. Tank shells may be of seamless construction.
- (b)Tanks must be designed, constructed, certified, and stamped in accordance with Section VIII of the ASME Code (IBR, see § 171.7 of this subchapter).
- (c)Tanks including all permanent attachments must be postweld heat treated as a unit.
- (d)Requirements concerning types of valves, retesting, and qualification of portable tanks contained in §§ 173.32 and 173.315 of this chapter must be observed.