49 CFR §178.348-5
- (a)Each cargo tank must be tested in accordance with § 178.345-13 and this section.
- (b)Pressure test. Test pressure must be as follows:
- (1)Using the hydrostatic test method, the test pressure must be at least 1.5 times MAWP.
- (2)Using the pneumatic test method, the test pressure must be at least 1.5 times tank MAWP, and the inspection pressure is tank MAWP.