49 CFR §195.305
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Each pressure test under § 195.302 must test all pipe and attached fittings, including components, unless otherwise permitted by paragraph (b) of this section.
- (b)A component, other than pipe, that is the only item being replaced or added to the pipeline system need not be hydrostatically tested under paragraph (a) of this section if the manufacturer certifies that either—