Any source that is a new source subject to this subpart must achieve the following performance standards:
(a) Facilities that slaughter no more than 100 million pounds per year (in units of LWK) must achieve the following performance standards:
Performance Standards
[NSPS]
Regulated parameter |
Maximum daily1 | Maximum monthly avg.1 |
---|---|---|
Ammonia (as N) | 8.0 | 4.0 |
BOD5 | 26 | 16 |
Fecal Coliform | (2) | (3) |
O&G (as HEM) | 14 | 8.0 |
TSS | 30 | 20 |
1mg/L (ppm).
2Maximum of 400 MPN or CFU per 100 mL at any time.
3No maximum monthly average limitation.
(b) Facilities that slaughter more than 100 million pounds per year (in units of LWK) must achieve the following performance standards:
Performance Standards
[NSPS]
Regulated parameter |
Maximum daily1 | Maximum monthly avg.1 |
---|---|---|
Ammonia (as N) | 8.0 | 4.0 |
BOD5 | 26 | 16 |
Fecal Coliform | (2) | (3) |
O&G (as HEM) | 14 | 8.0 |
TSS | 30 | 20 |
Total Nitrogen | 147 | 103 |
1mg/L (ppm).
2Maximum of 400 MPN or CFU per 100 mL at any time.
3No maximum monthly average limitation.