Any source that is a new source subject to this subpart must achieve the following performance standards:

(a) Facilities that further process no more than 7 million pounds per year (in units of finished product) must achieve the following performance standards:

Performance Standards

[NSPS]

Open Table
Regulated
parameter
Maximum daily1 Maximum monthly avg.1
Ammonia (as N) 8.0 4.0
BOD5 26 16
Fecal Coliform (2) (3)
O&G (as HEM) 14 8.0
TSS 30 20

1mg/L (ppm).

2Maximum of 400 MPN or CFU per 100 mL at any time.

3No maximum monthly average limitation.

(b) Facilities that further process more than 7 million pounds per year (in units of finished product) must achieve the following performance standards:

Effluent Limitations

[NSPS]

Open Table
Regulated
parameter
Maximum daily1 Maximum monthly avg.1
Ammonia (as N) 8.0 4.0
BOD5 26 16
Fecal Coliform (2) (3)
O&G (as HEM) 14 8.0
TSS 30 20
Total Nitrogen 147 103

1mg/L (ppm).

2Maximum of 400 MPN or CFU per 100 mL at any time.

3No maximum monthly average limitation.