Any source that is a new source subject to this subpart must achieve the following performance standards:
(a) Facilities that further process no more than 7 million pounds per year (in units of finished product) must achieve the following performance standards:
Performance Standards
[NSPS]
Regulated parameter |
Maximum daily1 | Maximum monthly avg.1 |
---|---|---|
Ammonia (as N) | 8.0 | 4.0 |
BOD5 | 26 | 16 |
Fecal Coliform | (2) | (3) |
O&G (as HEM) | 14 | 8.0 |
TSS | 30 | 20 |
1mg/L (ppm).
2Maximum of 400 MPN or CFU per 100 mL at any time.
3No maximum monthly average limitation.
(b) Facilities that further process more than 7 million pounds per year (in units of finished product) must achieve the following performance standards:
Effluent Limitations
[NSPS]
Regulated parameter |
Maximum daily1 | Maximum monthly avg.1 |
---|---|---|
Ammonia (as N) | 8.0 | 4.0 |
BOD5 | 26 | 16 |
Fecal Coliform | (2) | (3) |
O&G (as HEM) | 14 | 8.0 |
TSS | 30 | 20 |
Total Nitrogen | 147 | 103 |
1mg/L (ppm).
2Maximum of 400 MPN or CFU per 100 mL at any time.