40 CFR § 465.31
Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available
June 9, 2020
CFR

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available:

Subpart C

Open Table
Pollutant or pollutant property BPT Effluent limitations
Maximum for any 1 day Maximum for monthly average
               
    mg/m2 (pounds per 1 million ft2) of area processed
Chromium 1.42 (0.29) 0.58 (0.12)
Cyanide 0.98 (0.20) 0.41 (0.083)
Zinc 4.48 (0.92) 1.89 (0.39)
Aluminum 15.3 (3.14) 6.26. (1.28)
Oil and grease 67.3 (13.8) 40.4 (8.27)
TSS 138.0 (28.3) 67.3 (13.8)
pH (1) (1) (1) (1)

1Within the range of 7.5 to 10.0 at all times.

[47 FR 54244, Dec. 1, 1982; 49 FR 33649, Aug. 24, 1984]