Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable:

Subpart C

Open Table
Pollutant or pollutant property BAT Effluent limitations
Maximum for any 1 day Maximum for monthly average
               
    mg/m2 (pounds per 1 million ft2) of area processed
Chromium 0.42 (0.085) 0.17 (0.034)
Cyanide 0.29 (0.059) 0.12 (0.024)
Zinc 1.32 (0.27) 0.56 (0.12)
Aluminum 4.49 (0.92) 1.84. (0.38)

[47 FR 54244, Dec. 1, 1982; 49 FR 33649, Aug. 24, 1984]