Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources. The mass of wastewater pollutants in coil coating process wastewater introduced into a POTW shall not exceed the following values:

Subpart C

Open Table
Pollutant or pollutant property PSES
Maximum for any 1 day Maximum for monthly average
               
    mg/m2 (pounds per 1 million ft2) of area processed
Chromium 0.42 (0.085) 0.17 (0.034)
Cyanide 0.29 (0.059) 0.12 (0.024)
Zinc 1.32 (0.27) 0.56 (0.12)

[47 FR 54244, Dec. 1, 1982; 49 FR 33649, Aug. 24, 1984]