Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources. The mass of wastewater pollutants in coil coating process wastewater introduced into a POTW shall not exceed the following values:

Subpart C

Open Table
Pollutant or pollutant property PSNS
Maximum for any 1 day Maximum for monthly average
               
    mg/m2 (pounds per 1 million ft2) of area processed
Chromium 0.18 (0.037) 0.072 (0.015)
Cyanide 0.095 (0.02) 0.038 (0.008)
Zinc 0.49 (0.10) 0.20 (0.041)

[47 FR 54244, Dec. 1, 1982; 49 FR 33649, Aug. 24, 1984]


Tried the LawStack mobile app?

Join thousands and try LawStack mobile for FREE today.

  • Carry the law offline, wherever you go.
  • Download CFR, USC, rules, and state law to your mobile device.