Open Table
For the following existing sources .  .  . You must meet the emission limits for the specified pollutant .  .  .
Total fluorides
Phosphate Fertilizer Process Line (e.g., Diammonium and/or Monoammonium Phosphate Process Line) 0.060 lb/ton of equivalent P2O5 feed.
Granular Triple Superphosphate Process Line 0.150 lb/ton of equivalent P2O5 feed.
GTSP storage building 5.0 × 10−4 lb/hr/ton of equivalent P2O5 stored.

aThe existing source compliance date is June 10, 2002.

bDuring periods of startup and shutdown, for emission limits stated in terms of pounds of pollutant per ton of feed, you are subject to the work practice standards specified in §63.622(d).