As stated in §63.9820, you must comply with the applicable General Provisions requirements according to the following table:

Open Table
Citation Subject Brief description Applies to subpart SSSSS
§63.1 Applicability Yes.
§63.2 Definitions Yes.
§63.3 Units and Abbreviations Yes.
§63.4 Prohibited Activities Compliance date; circumvention, severability Yes.
§63.5 Construction/Reconstruction Applicability; applications; approvals Yes.
§63.6(a) Applicability General Provisions (GP) apply unless compliance extension; GP apply to area sources that become major Yes.
§63.6(b)(1)-(4) Compliance Dates for New and Reconstructed Sources Standards apply at effective date; 3 years after effective date; upon startup; 10 years after construction or reconstruction commences for section 112(f) Yes.
§63.6(b)(5) Notification Yes.
§63.6(b)(6) [Reserved]
§63.6(b)(7) Compliance Dates for New and Reconstructed Area Sources That Become Major Area sources that become major must comply with major source standards immediately upon becoming major, regardless of whether required to comply when they were area sources Yes.
§63.6(c)(1)-(2) Compliance Dates for Existing Sources Comply according to date in subpart, which must be no later than 3 years after effective date; for section 112(f) standards, comply within 90 days of effective date unless compliance extension Yes.
§63.6(c)(3)-(4) [Reserved]
§63.6(c)(5) Compliance Dates for Existing Area Sources That Become Major Area sources that become major must comply with major source standards by date indicated in subpart or by equivalent time period (for example, 3 years) Yes.
§63.6(d) [Reserved]
§63.6(e)(1)-(2) Operation & Maintenance Operate to minimize emissions at all times; correct malfunctions as soon as practicable; requirements independently enforceable; information Administrator will use to determine if operation and maintenance requirements were met Yes.
§63.6(e)(3) Startup, Shutdown, and Malfunction Plan (SSMP) Yes.
§63.6(f)(1) Compliance Except During SSM You must comply with emission standards at all times except during SSM Yes.
§63.6(f)(2)-(3) Methods for Determining Compliance Compliance based on performance test, operation and maintenance plans, records, inspection Yes.
§63.6(g)(1)-(3) Alternative Standard Procedures for getting an alternative standard. Yes.
§63.6(h)(1)-(9) Opacity/Visible Emission (VE) Standards Not applicable.
§63.6(i)(1)-(14) Compliance Extension Procedures and criteria for Administrator to grant compliance extension Yes.
§63.6(j) Presidential Compliance Exemption President may exempt source category Yes.
§63.7(a)(1)-(2) Performance Test Dates Dates for conducting initial performance testing and other compliance demonstrations; must conduct 180 days after first subject to rule Yes.
§63.7(a)(3) Section 114 Authority Administrator may require a performance test under CAA section 114 at any time Yes.
§63.7(b)(1) Notification of Performance Test Must notify Administrator 60 days before the test Yes.
§63.7(b)(2) Notification of Rescheduling Must notify Administrator 5 days before scheduled date and provide rescheduled date Yes.
§63.7(c) Quality Assurance/Test Plan Requirements; test plan approval procedures; performance audit requirements; internal and external QA procedures for testing Yes.
§63.7(d) Testing Facilities Yes.
§63.7(e)(1) Conditions for Conducting Performance Tests Performance tests must be conducted under representative conditions; cannot conduct performance tests during SSM; not a violation to exceed standard during SSM No, §63.9800 specifies requirements; Yes; Yes.
§63.7(e)(2) Conditions for Conducting Performance Tests Must conduct according to subpart and EPA test methods unless Administrator approves alternative Yes.
§63.7(e)(3) Test Run Duration Must have three test runs of at least 1 hour each; compliance is based on arithmetic mean of three runs; conditions when data from an additional test run can be used Yes; Yes, except where specified in §63.9800 for batch process sources; Yes.
§63.7(f) Alternative Test Method Yes.
§63.7(g) Performance Test Data Analysis Yes.
§63.7(h) Waiver of Test Yes.
§63.8(a)(1) Applicability of Monitoring Requirements Yes.
§63.8(a)(2) Performance Specifications Performance Specifications in appendix B of 40 CFR part 60 apply Yes.
§63.8(a)(3) [Reserved]
§63.8(a)(4) Monitoring with Flares Not applicable.
§63.8(b)(1) Monitoring Must conduct monitoring according to standard unless Administrator approves alternative Yes.
§63.8(b)(2)-(3) Multiple Effluents and Multiple Monitoring Systems Specific requirements for installing and reporting on monitoring systems Yes.
§63.8(c)(1) Monitoring System Operation and Maintenance Maintenance consistent with good air pollution control practices Yes.
§63.8(c)(1)(i) Routine and Predictable SSM Reporting requirements for SSM when action is described in SSMP Yes.
§63.8(c)(1)(ii) SSM not in SSMP Reporting requirements for SSM when action is not described in SSMP Yes.
§63.8(c)(1)(iii) Compliance with Operation and Maintenance Requirements How Administrator determines if source is complying with operation and maintenance requirements Yes.
§63.8(c)(2)-(3) Monitoring System Installation Must install to get representative emission and parameter measurements Yes.
§63.8(c)(4) CMS Requirements No, §63.9808 specifies requirements.
§63.8(c)(5) COMS Minimum Procedures Not applicable.
§63.8(c)(6) CMS Requirements Applies only to sources required to install and operate a THC CEMS.
§63.8(c)(7)(i)(A) CMS Requirements Applies only to sources required to install and operate a THC CEMS.
§63.8(c)(7)(i)(B) CMS Requirements Applies only to sources required to install and operate a THC CEMS.
§63.8(c)(7)(i)(C) CMS Requirements Not applicable.
§63.8(c)(7)(ii) CMS Requirements Corrective action required when CMS is out of control Yes.
§63.8(c)(8) CMS Requirements Yes.
§63.8(d) CMS Quality Control Applies only to sources required to install and operate a THC CEMS.
§63.8(e) CMS Performance Evaluation Applies only to sources required to install and operate a THC CEMS.
§63.8(f)(1)-(5) Alternative Monitoring Method Yes.
§63.8(f)(6) Alternative to Relative Accuracy Test Yes.
§63.8(g) Data Reduction Applies only to sources required to install and operate a THC CEMS.
§63.9(a) Notification Requirements Yes.
§63.9(b)(1)-(5) Initial Notifications Yes.
§63.9(c) Request for Compliance Extension Yes.
§63.9(d) Notification of Special Compliance Requirements for New Source Yes.
§63.9(e) Notification of Performance Test Notify Administrator 60 days prior Yes.
§63.9(f) Notification of VE/Opacity Test Not applicable.
§63.9(g) Additional Notifications When Using CMS Applies only to sources required to install and operate a THC CEMS.
§63.9(h) Notification of Compliance Status Yes.
§63.9(i) Adjustment of Submittal Deadlines Yes.
§63.9(j) Change in Previous Information Yes.
§63.10(a) Recordkeeping/Reporting Yes.
§63.10(b)(1) Recordkeeping/Reporting Yes.
§63.10(b)(2)(i)-(v) Records Related to Startup, Shutdown, and Malfunction Yes.
§63.10(b)(2)(vi) and (x-xi) CMS Records Yes.
§63.10(b)(2)(vii)-(ix) Records Measurements to demonstrate compliance with emission limitations; performance test, performance evaluation, and visible emission observation results; measurements to determine conditions of performance tests and performance evaluations Yes.
§63.10(b)(2)(xii) Records Records when under waiver Yes.
§63.10(b)(2)(xiii) Records Records when using alternative to relative accuracy test Not applicable.
§63.10(b)(2)(xiv) Records All documentation supporting Initial Notification and Notification of Compliance Status Yes.
§63.10(b)(3) Records Applicability Determinations Yes.
§63.10(c)(1)-(6), (9)-(15) Records Additional Records for CMS Not applicable.
§63.10(c)(7)-(8) Records Records of excess emissions and parameter monitoring exceedances for CMS No, §63.9816 specifies requirements.
§63.10(d)(1) General Reporting Requirements Requirements for reporting Yes.
§63.10(d)(2) Report of Performance Test Results When to submit to Federal or State authority Yes.
§63.10(d)(3) Reporting Opacity or VE Observations Not applicable.
§63.10(d)(4) Progress Reports Must submit progress reports on schedule if under compliance extension Yes.
§63.10(d)(5) Startup, Shutdown, and Malfunction Reports Contents and submission Yes.
§63.10(e)(1)-(2) Additional CMS Reports Applies only to sources required to install and operate a THC CEMS.
§63.10(e)(3) Reports No, §63.9814 specifies requirements.
§63.10(e)(4) Reporting COMS data Not applicable.
§63.10(f) Waiver for Recordkeeping/Reporting Yes.
§63.11 Flares Not applicable.
§63.12 Delegation Yes.
§63.13 Addresses Yes.
§63.14 Incorporation by Reference Yes.
§63.15 Availability of Information Yes.