As required in §63.9590(a), you must comply with each applicable emission limit in the following table:

Open Table
If your affected source is .  .  . and the affected source is categorized as .  .  . then you must comply with the flow-weighted mean concentration of particulate matter discharged to the atmosphere from the affected source, as determined using the procedures in §63.9621(b), such that you must not exceed .  .  .
1. Ore crushing and handling emission units Existing 0.008 grains per dry standard cubic foot (gr/dscf).
    New 0.005 gr/dscf.
2. Straight grate indurating furnace processing magnetite Existing
New
0.01 gr/dscf.
0.006 gr/dscf.
3. Grate kiln indurating furnace processing magnetite Existing
New
0.01 gr/dscf.
0.006 gr/dscf.
4. Grate kiln indurating furnace processing hematite Existing
New
0.03 gr/dscf.
0.018 gr/dscf.
5. Finished pellet handling emission units Existing
New
0.008 gr/dscf.
0.005 gr/dscf.
6. Ore dryer Existing
New
0.052 gr/dscf.
0.025 gr/dscf.

Tried the LawStack mobile app?