As stated in §63.1566(c)(1), you shall meet each requirement in the following table that applies to you.

Open Table
For each applicable process vent for a new or existing catalytic reforming unit .  .  . For this emission limit .  .  . You shall demonstrate continuous compliance during initial catalyst depressuring and catalyst purging operations by .  .  .
1. Option 1 Vent emissions from your process vent to a flare On and after January 30, 2019, meeting the requirements of §63.670. Prior to January 30, 2019, maintaining visible emissions from a flare below a total of 5 minutes during any 2 consecutive hours, or meeting the requirements of §63.670.
2. Option 2 Reduce uncontrolled emissions of total organic compounds (TOC) or nonmethane TOC from your process vent by 98 percent by weight using a control device or to a concentration of 20 ppmv (dry basis as hexane), corrected to 3 percent oxygen, whichever is less stringent. Maintaining a 98 percent by weight emission reduction of TOC or nonmethane TOC; or maintaining a TOC or nonmethane TOC concentration of not more than 20 ppmv (dry basis as hexane), corrected to 3 percent oxygen, whichever is less stringent.

[70 FR 6954, Feb. 9, 2005, as amended at 80 FR 75305, Dec. 1, 2015]