As stated in §60.2916, you must comply with the following:

Open Table
For these operating
parameters
You must establish these operating limits And monitoring using these minimum frequencies
Data measurement Data recording Averaging time
1. Charge rate Maximum charge rate Continuous Every hour Daily for batch units. 3-hour rolling for continuous and intermittent unitsa.
2. Pressure drop across the wet scrubber or amperage to wet scrubber Minimum pressure drop or amperage Continuous Every 15 minutes 3-hour rollinga.
3. Scrubber liquor flow rate Minimum flow rate Continuous Every 15 minutes 3-hour rollinga.
4. Scrubber liquor pH Minimum pH Continuous Every 15 minutes 3-hour rollinga.

aCalculated each hour as the average of the previous 3 operating hours.