Citation | Subject | Applies to Subpart FFFFF | Explanation |
---|---|---|---|
§63.1 | Applicability | Yes. | |
§63.2 | Definitions | Yes. | |
§63.3 | Units and Abbreviations | Yes. | |
§63.4 | Prohibited Activities | Yes. | |
§63.5 | Construction/Reconstruction | Yes. | |
§63.6(a), (b), (c), (d), (e), (f), (g), (h)(2)(ii)-(h)(9) | Compliance with Standards and Maintenance Requirements | Yes. | |
§63.6(h)(2)(i) | Determining Compliance with Opacity and VE Standards | No | Subpart FFFFF specifies methods and procedures for determining compliance with opacity emission and operating limits. |
§63.6(i) | Extension of Compliance with Emission Standards | Yes | |
§63.6(j) | Exemption from Compliance with Emission Standards | Yes | |
§63.7(a)(1)-(2) | Applicability and Performance Test Dates | No | Subpart FFFFF and specifies performance test applicability and dates. |
§63.7(a)(3), (b), (c)-(h) | Performance Testing Requirements | Yes | |
§63.8(a)(1)-(3), (b), (c)(1)-(3), (c)(4)(i)-(ii), (c)(5)-(6), (c)(7)-(8), (f)(1)-(5), (g)(1)-(4) | Monitoring Requirements | Yes | CMS requirements in §§63.8(c)(4)(i)-(ii), (c)(5)-(6), (d), and (e) apply only to COMS. |
§63.8(a)(4) | Additional Monitoring Requirements for Control Devices in §63.11 | No | Subpart FFFFF does not require flares. |
§63.8(c)(4) | Continuous Monitoring System Requirements | No | Subpart FFFFF specifies requirements for operation of CMS. |
§63.8(f)(6) | RATA Alternative | No | |
§63.8(g)(5) | Data Reduction | No | Subpart FFFFF specifies data reduction requirements. |
§63.9 | Notification Requirements | Yes | Additional notifications for CMS in §63.9(g) apply only to COMS. |
§63.10(a), (b)(1), (b)(2)(i)-(xii), (b)(2)(xiv), (b)(3), (c)(1)-(6), (c)(9)-(15), (d), (e)(1)-(2), (e)(4), (f) | Recordkeeping and Reporting Requirements | Yes | Additional records for CMS in §63.10(c)(1)-(6), (9)-(15), and reports in §63.10(d)(1)-(2) apply only to COMS. |
§63.10(b)(2) (xiii) | CMS Records for RATA Alternative | No | |
§63.10(c)(7)-(8) | Records of Excess Emissions and Parameter Monitoring Exceedances for CMS | No | Subpart FFFFF specifies record requirements. |
§63.10(e)(3) | Excess Emission Reports | No | Subpart FFFFF specifies reporting requirements |
§63.11 | Control Device Requirements | No | Subpart FFFFF does not require flares. |
§63.12 | State Authority and Delegations | Yes. | |
§63.13-§63.15 | Addresses, Incorporation by Reference, Availability of Information | Yes. |
[68 FR 27663, May 20, 2003, as amended at 71 FR 39591, July 13, 2006]