As stated in §63.9810, you must show continuous compliance with the work practice standards for affected sources according to the following table:

Open Table
For .  .  .   For the following work practice standard .  .  . You must demonstrate continuous compliance by .  .  .
1. Each affected source listed in Table 3 to this subpart Each applicable work practice requirement listed in Table 3 to this subpart i. Performing each applicable work practice standard listed in Table 3 to this subpart; and
    ii. Maintaining records that document the method and frequency for complying with each applicable work practice standard listed in Table 3 to this subpart, as required by §§63.10(b) and 63.9816(c)(2).
2. Each basket or container that is used for holding fired refractory shapes in an existing shape preheater and autoclave during the pitch impregnation process Control POM emissions from any affected shape preheater i. Controlling emissions from the volatilization of residual pitch by implementing one of the work practice standards listed in item 1 of Table 3 to this subpart; and
    ii. Recording the date and cleaning method each time you clean an affected basket or container.
3. Each new or existing pitch working tank Control POM emissions Capturing and venting emissions from the affected pitch working tank to the control device that is used to control emissions from an affected defumer or coking oven, or to a thermal or catalytic oxidizer that is comparable to the control device used on an affected defumer or coking oven.
4. Each new or existing chromium refractory products kiln Minimize fuel-based HAP emissions i. Using natural gas, or equivalent, as the kiln fuel at all times except during periods of natural gas curtailment or supply interruption; and
    ii. If you intend to use an alternative fuel, submitting a notification of alternative fuel use within 48 hours of the declaration of a per-iod of natural gas curtailment or supply interruption, as defined in §63.9824; and
    iii. Submitting a report of alternative fuel use within 10 working days after terminating the use of the alternative fuel, as specified in §63.9814(g).
5. Each existing clay refractory products kiln Minimize fuel-based HAP emissions i. Using natural gas, or equivalent, as the kiln fuel at all times except during periods of natural gas curtailment or supply interruption; and
    ii. If you intend to use an alternative fuel, submitting a notification of alternative fuel use within 48 hours of the declaration of a per-iod of natural gas curtailment or supply interruption, as defined in §63.9824; and
    iii. Submitting a report of alternative fuel use within 10 working days after terminating the use of the alternative fuel, as specified in §63.9814(g).