40 CFR § 405.82
Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available
June 9, 2020
CFR

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) For plants with a dairy products input of more than 85,000 lb/day of milk equivalent (more than 8,830 lb/day of BOD5 input).

Open Table
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of BOD5 input)
BOD5 4.60 1.840
TSS 6.90 2.760
pH (1) (1)
English units (pounds per 100 lb of BOD5 input)
BOD5 0.460 0.184
TSS .690 0.276
pH (1) (1)

1Within the range 6.0 to 9.0.

(b) For plants with a dairy products input of 85,000 lb/day or less of milk equivalent (less than 8,830 lb/day of BOD5 input).

Open Table
Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of BOD5 input)
BOD5 6.126 3.063
TSS 9.188 4.594
pH (1) (1)
English units (pounds per 100 lb of BOD5 input)
BOD5 0.613 0.306
TSS .919 .459
pH (1) (1)

1Within the range 6.0 to 9.0.

[39 FR 18597, May 28, 1974, as amended at 60 FR 33934, June 29, 1995]