40 CFR §63.7918
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7915 applicable to your affected transfer system by meeting the requirements in paragraphs (b) through (e) of this section as applicable to your transfer systems.
- (b)You must demonstrate continuous compliance for each individual drain system using controls according to § 63.7915(b) by meeting the requirements in paragraphs (b)(1) through (5) of this section.
- (1)Operating and maintaining the air emission controls for individual drain systems according to the requirements in § 63.962.
- (2)Visually inspecting each individual drain system at least annually according to the requirements in § 63.964(a).
- (3)Repairing defects according to the requirements in § 63.964(b).
- (4)Recording the information specified in § 63.965(a).
- (5)Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
- (c)You must demonstrate continuous compliance for each transfer system using covers according to § 63.7915(c)(1) by meeting the requirements in paragraphs (c)(1) through (4) of this section.
- (1)Operating and maintaining each cover and its closure devices according to the requirements in § 63.689(d)(1) through (5).
- (2)Performing inspections of each cover and its closure devices for defects at least annually according to the requirements in § 63.695(d)(1) through (5).
- (3)Repairing defects according to the requirements in § 63.695(5)
- (4)Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
- (d)You must demonstrate continuous compliance for each transfer system that consists of hard piping according to § 63.7915(c)(2) by meeting the requirements in paragraphs (d)(1) through (4) of this section.
- (1)Operating and maintaining the pipeline to ensure that all joints or seams between the pipe sections remain permanently or semi-permanently sealed (e.g., a welded joint between two sections of metal pipe or a bolted and gasketed flange).
- (2)Inspecting the pipeline for defects at least annually according to the requirements in § 63.7917(c).
- (3)Repairing defects according to the requirements in § 63.7917(e).
- (4)Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
- (e)You must demonstrate continuous compliance for each transfer system that is enclosed and vented to a control device according to § 63.7915(c)(3) by meeting the requirements in paragraphs (e)(1) through (5) of this section.
- (1)Operating and maintaining the enclosure to ensure that the internal pressure in the vapor headspace in the enclosure is maintained continuously at a level less than atmospheric pressure when the control device is operating.
- (2)Inspecting the enclosure and its closure devices for defects at least annually according to the requirements in § 63.7918(d).
- (3)Repairing defects according to the requirements in § 63.7918(e).
- (4)Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
- (5)Keeping records to document compliance with the requirements according to the requirements in § 63.7952.