- (a)At least 8 hours, but not more than 56 hours before the test, place each filter in an open, but protected, petri dish and place in the weighing chamber which meets the humidity and temperature specifications of § 86.112.
- (b)At the end of the 8 to 56 hour stabilization period, weigh the filter on a balance having a precision of one microgram. Record this weight. This reading is the tare weight.
- (c)The filter shall then be stored in a covered petri dish which shall remain in the weighing chamber until needed for testing.
- (d)
- (e)After the test, and after the sample filter is returned to the weighing room, condition it for at least 1 hour but not more than 56 hours. Then weigh a second time. This latter reading is the gross weight of the filter. Record this weight.
- (f)The net weight (Pe) is the gross weight minus the tare weight.