40 CFR Table 27 to Subpart G of Part 63
Summary of Internal Floating Deck Fitting Loss Factors (KF) and Typical Number of Fittings (NF)
June 9, 2020
Open Table
Deck fitting type | Deck fitting loss factor (KF)a | Typical number of fittings (NF) |
---|---|---|
Access hatch | 1. | |
Bolted cover, gasketed | 1.6 | |
Unbolted cover, gasketed | 11 | |
Unbolted cover, ungasketed | b25 | |
Automatic gauge float well | 1. | |
Bolted cover, gasketed | 5.1 | |
Unbolted cover, gasketed | 15 | |
Unbolted cover, ungasketed | b28 | |
Column well | (see Table 24). | |
Builtup column-sliding cover, gasketed | 33 | |
Builtup column-sliding cover, ungasketed |
b47 10 |
|
Pipe column-flexible fabric sleeve seal | 19 | |
Pipe column-sliding cover, gasketed | 32 | |
Pipe column-sliding cover, ungasketed | ||
Ladder well | 1. | |
Sliding cover, gasketed | 56 | |
Sliding cover, ungasketed | b76 | |
Roof leg or hanger well | (5 + D/10 + D2/600)c. | |
Adjustable | b7.9 | |
Fixed | 0 | |
Sample pipe or well | 1. | |
Slotted pipe-sliding cover, gasketed | 44 | |
Slotted pipe-sliding cover, ungasketed | 57 | |
Sample well-slit fabric seal, 10 percent open area | b12 | |
Stub drain, 1-in diameterd | 1.2 | (D2/125)c. |
Vacuum breaker | 1. | |
Weighted mechanical actuation, gasketed | b0.7 | |
Weighted mechanical actuation, ungasketed | 0.9 |
aUnits for KF are pound-moles per year.
bIf no specific information is available, this value can be assumed to represent the most common/typical deck fittings currently used.
cD = Tank diameter (feet).
dNot used on welded contact internal floating decks.