Open Table
Deck fitting type Deck fitting loss factor (KF)a Typical number of fittings (NF)
Access hatch 1.
Bolted cover, gasketed 1.6
Unbolted cover, gasketed 11
Unbolted cover, ungasketed b25
Automatic gauge float well 1.
Bolted cover, gasketed 5.1
Unbolted cover, gasketed 15
Unbolted cover, ungasketed b28
Column well (see Table 24).
Builtup column-sliding cover, gasketed 33
Builtup column-sliding cover, ungasketed b47
10
Pipe column-flexible fabric sleeve seal 19
Pipe column-sliding cover, gasketed 32
Pipe column-sliding cover, ungasketed
Ladder well 1.
Sliding cover, gasketed 56
Sliding cover, ungasketed b76
Roof leg or hanger well (5 + D/10 + D2/600)c.
Adjustable b7.9
Fixed 0
Sample pipe or well 1.
Slotted pipe-sliding cover, gasketed 44
Slotted pipe-sliding cover, ungasketed 57
Sample well-slit fabric seal, 10 percent open area b12
Stub drain, 1-in diameterd 1.2 (D2/125)c.
Vacuum breaker 1.
Weighted mechanical actuation, gasketed b0.7
Weighted mechanical actuation, ungasketed 0.9

aUnits for KF are pound-moles per year.

bIf no specific information is available, this value can be assumed to represent the most common/typical deck fittings currently used.

cD = Tank diameter (feet).

dNot used on welded contact internal floating decks.