40 CFR Subpart G
National Emission Standards for Organic Hazardous Air Pollutants From the Synthetic Organic Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater
June 9, 2020
§
63.111
Definitions
§
63.112
Emission standard
§
63.113
Process vent provisions—reference control technology
§
63.114
Process vent provisions—monitoring requirements
§
63.115
Process vent provisions—methods and procedures for process vent group determination
§
63.116
Process vent provisions—performance test methods and procedures to determine compliance
§
63.117
Process vent provisions—reporting and recordkeeping requirements for group and TRE determinations and performance tests
§
63.118
Process vent provisions—periodic reporting and recordkeeping requirements
§
63.119
Storage vessel provisions—reference control technology
§
63.120
Storage vessel provisions—procedures to determine compliance
§
63.110
Applicability
§
63.121
Storage vessel provisions—alternative means of emission limitation
§
63.122
Storage vessel provisions—reporting
§
63.123
Storage vessel provisions—recordkeeping
§
§63.124-63.125
[Reserved]
§
63.126
Transfer operations provisions—reference control technology
§
63.127
Transfer operations provisions—monitoring requirements
§
63.128
Transfer operations provisions—test methods and procedures
§
63.129
Transfer operations provisions—reporting and recordkeeping for performance tests and notification of compliance status
§
63.130
Transfer operations provisions—periodic recordkeeping and reporting
§
63.131
[Reserved]
§
63.132
Process wastewater provisions—general
§
63.133
Process wastewater provisions—wastewater tanks
§
63.134
Process wastewater provisions—surface impoundments
§
63.135
Process wastewater provisions—containers
§
63.136
Process wastewater provisions—individual drain systems
§
63.137
Process wastewater provisions—oil-water separators
§
63.138
Process wastewater provisions—performance standards for treatment processes managing Group 1 wastewater streams and/or residuals removed from Group 1 wastewater streams
§
63.139
Process wastewater provisions—control devices
Table
1 to Subpart G of Part 63
Process Vents—Coefficients for Total Resource Effectiveness for Existing Source Nonhalogenated and Halogenated Vent Streams
§
63.140
Process wastewater provisions—delay of repair
§
§63.141-63.142
[Reserved]
§
63.143
Process wastewater provisions—inspections and monitoring of operations
§
63.144
Process wastewater provisions—test methods and procedures for determining applicability and Group 1/Group 2 determinations (determining which wastewater streams require control)
§
63.145
Process wastewater provisions—test methods and procedures to determine compliance
§
63.146
Process wastewater provisions—reporting
§
63.147
Process wastewater provisions—recordkeeping
§
63.148
Leak inspection provisions
§
63.149
Control requirements for certain liquid streams in open systems within a chemical manufacturing process unit
§
63.150
Emissions averaging provisions
§
63.151
Initial notification
§
63.152
General reporting and continuous records
§
63.153
Implementation and enforcement
Table
1A to Subpart G of Part 63
Applicable 40 CFR Part 63 General Provisions
Table
2 to Subpart G of Part 63
Process Vents—Coefficients for Total Resource Effectiveness for New Source Nonhalogenated and Halogenated Vent Streams
Table
3 to Subpart G of Part 63
Process Vents—Monitoring, Recordkeeping, and Reporting Requirements for Complying With 98 Weight-Percent Reduction of Total Organic Hazardous Air Pollutants Emissions or a Limit of 20 Parts Per Million by Volume
Table
4 to Subpart G of Part 63
Process Vents—Monitoring, Recordkeeping, and Reporting Requirements For Maintaining a TRE Index Value >1.0 and. ≤4.0
Table
5 to Subpart G of Part 63
Group 1 Storage Vessels at Existing Sources
Table
6 to Subpart G of Part 63
Group 1 Storage Vessels at New Sources
Table
7 to Subpart G of Part 63
Transfer Operations—Monitoring, Recordkeeping, and Reporting Requirements for Complying With 98 Weight-Percent Reduction of Total Organic Hazardous Air Pollutants Emissions or a Limit of 20 Parts Per Million by Volume
Table
8 to Subpart G of Part 63
Organic HAP's Subject to the Wastewater Provisions for Process Units at New Sources
Table
9 to Subpart G of Part 63
Organic HAP's Subject to the Wastewater Provisions for Process Units at New and Existing Sources and Corresponding Fraction Removed (Fr) Values
Table
10 to Subpart G of Part 63
Wastewater—Compliance Options for Wastewater Tanks
Table
11 to Subpart G of Part 63
Wastewater—Inspection and Monitoring Requirements for Waste Management Units
Table
12 to Subpart G of Part 63
Monitoring Requirements for Treatment Processes
Table
13 to Subpart G of Part 63
Wastewater—Monitoring Requirements for Control Devices
Tables 14-14b to Subpart G of Part 63 [Reserved]
Table
15 to Subpart G of Part 63
Wastewater—Information on Table 8 and/or Table 9 Compounds To Be Submitted With Notification of Compliance Status for Process Units at New and/or Existing Sources
Table
16 to Subpart G of Part 63 [Reserved]
Table
17 to Subpart G of Part 63
Information for Treatment Processes To Be Submitted With Notification of Compliance Status
Table
18 to Subpart G of Part 63
Information for Waste Management Units To Be Submitted With Notification of Compliance Status
Table
19 to Subpart G of Part 63
Wastewater—Information on Residuals To Be Submitted With Notification of Compliance Status
Table
20 to Subpart G of Part 63
Wastewater—Periodic Reporting Requirements for Control Devices Subject to §63.139 Used To Comply With §§63.13 Through 63.139
Table
21 to Subpart G of Part 63
Average Storage Temperature (Ts) as a Function of Tank Paint Color
Table
22 to Subpart G of Part 63
Paint Factors for Fixed Roof Tanks
Table
23 to Subpart G of Part 63
Average Clingage Factors (c)
Table
24 to Subpart G of Part 63
Typical Number of Columns as a Function of Tank Diameter for Internal Floating Roof Tanks With Column Supported Fixed Roofs
Table
25 to Subpart G of Part 63
Effective Column Diameter (Fc)
Table
26 to Subpart G of Part 63
Seal Related Factors for Internal Floating Roof Vessels
Table
27 to Subpart G of Part 63
Summary of Internal Floating Deck Fitting Loss Factors (KF) and Typical Number of Fittings (NF)
Table
28 to Subpart G of Part 63
Deck Seam Length Factors (SD) for Internal Floating Roof Tanks
Table
29 to Subpart G of Part 63
Seal Related Factors for External Floating Roof Vessels
Table
30 to Subpart G of Part 63
Roof Fitting Loss Factors, KFa, KFb, and m, and Typical Number of Fittings, NT
Table
31 to Subpart G of Part 63
Typical Number of Vacuum Breakers, NF6 and Roof Drains, NF7
Table
32 to Subpart G of Part 63
Typical Number of Roof Legs, NF8
Table
33 to Subpart G of Part 63
Saturation Factors
Table
34 to Subpart G of Part 63
Fraction Measured (Fm) and Fraction Emitted (Fe) For HAP Compounds in Wastewater Streams
Table
35 to Subpart G of Part 63
Control Requirements for Items of Equipment That Meet the Criteria of §63.149 of Subpart G
Table
36 to Subpart G of Part 63
Compound Lists Used for Compliance Demonstrations for Enhanced Biological Treatment Processes (See §63.145(h))
Table
37 to Subpart G of Part 63
Default Biorates for List 1 Compounds
Figure
1
Figure 1 to Subpart G of Part 63—Definitions of Terms Used in Wastewater Equations

Tried the LawStack mobile app?

Join thousands and try LawStack mobile for FREE today.

  • Carry the law offline, wherever you go.
  • Download CFR, USC, rules, and state law to your mobile device.