Part 162 — Engineering Equipment
Subpart 162.017 — General Provisions; Valves, Pressure-Vacuum Relief, for Tank Vessels
Subpart 162.018 — Safety Relief Valves, Liquefied Compressed Gas
Subpart 162.027 — Combination Firehose Nozzles
Subpart 162.028 — Extinguishers, Fire, Portable, Marine Type
- § 162.028-1— Incorporation by reference.
- § 162.028-2— Classification.
- § 162.028-3— Requirements.
- § 162.028-4— Marine type label.
- § 162.028-5— Recognized laboratories.
- § 162.028-6— Examinations, tests, and inspections.
- § 162.028-7— Procedure for listing and labeling.
- § 162.028-8— Termination of listing or labeling.
Subpart 162.039 — Extinguishers, Fire, Semi-portable, Marine Type
- § 162.039-1— Incorporation by reference.
- § 162.039-2— Classification.
- § 162.039-3— Requirements.
- § 162.039-4— Marine type label.
- § 162.039-5— Recognized laboratories.
- § 162.039-6— Examinations, tests, and inspections.
- § 162.039-7— Procedure for listing and labeling.
- § 162.039-8— Termination of listing or labeling.
Subpart 162.050 — Pollution Prevention Equipment
- § 162.050-1— Scope.
- § 162.050-3— Definitions.
- § 162.050-4— Incorporation by reference: Where can I get a copy of the publications mentioned in this part?
- § 162.050-5— Contents of application.
- § 162.050-7— Approval procedures.
- § 162.050-9— Test report.
- § 162.050-11— Marking.
- § 162.050-13— Factory production and inspection.
- § 162.050-15— Designation of facilities.
- § 162.050-17— Separator test rig.
- § 162.050-19— Oil content meter and bilge alarm test rig.
- § 162.050-20— Separator and bilge alarm test fluids.
- § 162.050-21— Separator: Design specification.
- § 162.050-23— Separator: Approval tests.
- § 162.050-25— Cargo monitor: Design specification.
- § 162.050-27— Oil content meter: Approval tests.
- § 162.050-33— Bilge alarm: Design specification.
- § 162.050-35— Bilge alarm: Approval tests.
- § 162.050-37— Vibration test.
- § 162.050-39— Measurement of oil content.
Subpart 162.060 — Ballast Water Management Systems
- § 162.060-1— Purpose and scope.
- § 162.060-3— Definitions.
- § 162.060-5— Incorporation by reference.
- § 162.060-10— Approval procedures.
- § 162.060-12— Use and acceptance of existing test data.
- § 162.060-14— Information requirements for the ballast water management system (BWMS) application.
- § 162.060-16— Changes to an approved ballast water management system (BWMS).
- § 162.060-18— Suspension, withdrawal, or termination of approval.
- § 162.060-20— Design and construction requirements.
- § 162.060-22— Marking requirements.
- § 162.060-24— Test Plan requirements.
- § 162.060-26— Land-based testing requirements.
- § 162.060-28— Shipboard testing requirements.
- § 162.060-30— Testing requirements for ballast water management system (BWMS) components.
- § 162.060-32— Testing and evaluation requirements for active substances, preparations, and relevant chemicals.
- § 162.060-34— Test Report requirements.
- § 162.060-36— Quality Assurance Project Plan (QAPP) requirements.
- § 162.060-38— Operation, Maintenance, and Safety Manual (OMSM).
- § 162.060-40— Requirements for Independent Laboratories (ILs).
- § 162.060-42— Responsibilities for Independent Laboratories (ILs).
Subpart 162.161 — Fixed Clean Agent Fire Extinguishing Systems
- § 162.161-1— Scope.
- § 162.161-2— Incorporation by reference.
- § 162.161-3— Materials.
- § 162.161-4— Construction.
- § 162.161-5— Instruction manual for design, installation, operation, and maintenance.
- § 162.161-6— Tests for approval.
- § 162.161-7— Inspections at production.
- § 162.161-8— Marking.
- § 162.161-9— Procedure for approval.